- Product: CUMMINS
- Alternator: ECO 43-2M/4 A
- CONTROL SYSTEM: DSE 7320
Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.
Certificate
- TS ISO 8528
- CE
- SZUTEST
- 2000/14/EC
General Characteristics
Model Name | AC 1250 |
Frequency (Hz) | 50 |
Fuel Type | Diesel |
Engine Made and Model | CUMMINS - KTA38G9 |
Alternator Made and Model | Mecc Alte - ECO 43-2M/4 A |
Control Panel Model | DSE 7320 |
Canopy | AK 96-AC1250 |
3 Phase, 50 Hz, PF 0.8
VOLTAGE | STANDBY RATING (ESP) | PRIME RATING (PRP) | Standby Amper | ||
kVA | kW | kVA | kW | ||
400/231 | 1250 | 1000.00 | - | 1804.27 | |
STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed.
PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.
ENGINE SPECIFICATIONS
Engine | CUMMINS | |
Engine Model | KTA38G9 | |
NO. OF CYLINDERS AND BUILD | 12 cylinders - V type | |
BORE AND STROKE | mm | 159 X 159 |
TOTAL DISPLACEMENT | L | 37,8 |
Aspiration | Turbo Charged and AfterCooled | |
COMPRESSION RATIO | 13.9:1 | |
RATED SPEED (RPM) | d/dk | 1500 |
OIL CAPACITY | L | 135 |
Standby Power (kW/HP) | 1090/1460 | |
Block Heater QTY | 2 | |
Block Heater Power (Watt) | 4000 | |
Fuel Type | Diesel | |
Injection Type and System | Direct | |
Type of Fuel Pump | Cummins PT | |
Governor System | Electronic | |
Operating Voltage (Vdc) | 24 Vdc | |
Battery and Capacity (Qty/Ah) | 4x150Ah | |
Cooling Method | Water Cooled | |
Cooling Fan Air Flow (m3/min) | 1280 | |
Coolant Capacity (engine only / with radiator) (lt) | 279 | |
Air Filter | Dry Type | |
Fuel Cons. Prime With %100 Load (lt/hr) | 225 | |
Fuel Cons. Prime With %75 Load (lt/hr) | 168,7 | |
Fuel Cons. Prime With %50 Load (lt/hr) | 112,5 | |
ALTERNATOR SPECIFICATIONS
Manufacturer | Mecc Alte | |
Alternator Made and Model | ECO 43-2M/4 A | |
Frequency (Hz) | Hz | 50 |
Power (kVA) | kVA | 1150 |
DESIGN | 4 Pole, Brushless | |
VOLTAGE | V | 400 |
Phase | 3 | |
A.V.R. | DER1 | |
Voltage Regulation | (+/-) | 0,5% |
Insulation System | H | |
Protection | IP23 | |
Rated Power Factor | 0.8 | |
WEIGHT COMP. GENERATOR (Kg) | 2395 | |
COOLING AIR (m³/min) | m3 | 90 |
SIZE and WEIGHT
Open Type | DRY WEIGHT (kg.) | LENGTH | WIDTH | HEIGHT | TANK CAPACITY (lt.) (Lt.) |
8800 | 4510 | 1770 | 2438 | 1500 | |
CANOPY | DRY WEIGHT (kg.) | LENGTH | WIDTH | HEIGHT | TANK CAPACITY (lt.) (Lt.) |
AK 96-AC1250 | 12500 | 7500 | 2300 | 2508 | 1500 |
STANDARD SPECIFICATIONS
Water cooled diesel engine
Radiator with mechanical fan
Protective grille for rotating and hot parts
Electric starter and charge alternator
Starting battery (with lead acid) including rack and cables
Engine coolant heater
Steel base frame and anti-vibration isolators
Spare external fuel tank (open set)
Flexible fuel connection hoses
Single bearing, class H alternator
Industrial exhaust silencer and steel bellows supplied separately
Static battery charger
Manual for application and installation
Generators Sets’ voltage and frequency regulation comply with ISO 8528-5
OPTIONAL EQUIPMENTS
ENGINE
• Remote Radiator Cooling• Fuel-Water Seperator Filter
• Oil heater
ALTERNATOR
• Anti-Condensation Heater• Over sized alternator
• Main line circuit breaker
CONTROL SYSTEM
• Automatic synchronising and power control system ( multi gen-set Parallel )• Paralel system with mains.
• Transition synchronization with mains
• Remote annunciator panel
• Remote relay output
• Alarm output relays
• Earth fault, single set
• Charge Ammeter
TRANSFER SWITCH
• Three or four pole contactor• Three or four pole motor operated circuit breaker
OTHER ACCESSORIES
• Main Fuel Tank• Automatic or manual fuel filling system
• Electrical oil drain pump
• Low and high fuel level alarm
• Residential silencer
• Enclosure: weater protective or sound attenuated
• Duct adapter ( on radiator)
• Inlet and outlet motorised louvers
• Inlet and outlet acoustic baffles
• Tool kit for maintenance
• 1500/3000 hours maintenance kit
• Supplied with oil and coolant - 30 °C
Power Unleashed: The Aksa 1250 KVA Diesel Generator (AC1250)
In a world where a consistent power supply is the backbone of countless industries and essential services, the Aksa 1250 KVA Diesel Generator, also known as the AC1250, emerges as a beacon of reliability and power. With a colossal 1250 KVA capacity, it's a versatile and robust source of electricity for a wide range of applications. In this detailed blog, we will explore the various aspects of the AC1250, from its key features to applications and maintenance tips.
Key Features
- Raw Power Unleashed:
- The AC1250 Diesel Generator boasts an impressive 1250 KVA capacity, making it ideal for applications that require a substantial power supply. Whether you're running a massive industrial facility or need backup power for critical operations, the AC1250 has the muscle to deliver.
- Fuel Efficiency at Its Best:
- Powered by a reliable and efficient diesel engine, the AC1250 ensures cost-effective operation. Its fuel efficiency keeps operational costs in check while delivering a continuous power supply.
- Unmatched Reliability:
- When the lights go out, you need a generator you can trust. The AC1250 is engineered for reliability, with premium components that guarantee uninterrupted power during extended outages.
- Versatility Beyond Compare:
- This generator adapts seamlessly to various environments and applications. It can serve as a primary power source or stand as a robust backup solution, making it an ideal choice for a wide range of industries.
- Advanced Control and Monitoring:
- The digital control panel offers user-friendly features, including remote monitoring and automated testing. This allows you to maintain full control of your backup power supply, no matter where you are.
Applications
The AC1250 Diesel Generator is versatile and finds application in numerous sectors, including:
- Large-scale manufacturing facilities
- Data centers
- Hospitals and healthcare facilities
- Telecommunications and data networks
- Mining operations
- Construction sites
- Agricultural operations
- Events and entertainment venues
Maintenance
Regular maintenance is essential to ensure optimal generator performance. Here are some maintenance tips for the AC1250:
- Regular oil changes and filter replacements
- Routine checks of the cooling system and radiator
- Inspections of electrical connections
- Monitoring of the control panel for any alarms or warnings
Safety Precautions
Safety should be a top priority when operating the AC1250 generator. Always follow these safety guidelines:
- Maintain proper ventilation in the generator room to prevent exhaust buildup.
- Regularly inspect and clean the generator and surrounding area.
- Ensure that operators are adequately trained to handle the generator safely.
Environmental Compliance
The AC1250 Diesel Generator complies with emissions and environmental regulations, offering an eco-friendly power solution for modern industries.
Conclusion
The Aksa 1250 KVA Diesel Generator (AC1250) is a testament to the evolution of power generation technology. It ensures uninterrupted power, offering a lifeline to industries and services that rely on electricity. With its remarkable features, adaptability, and reliability, the AC1250 is more than a generator; it's a comprehensive power solution for the modern world. For the most up-to-date information on the AC1250 and its specifications, please consult Aksa or an authorized distributor.