Full Specification of AP 88 Diesel Generator With Details Guide!
For Quotation Please Contact:
Mobile/WhatsApp: +880 1816 553327 "or" +880 1730848516
E-Mail: "info@merlintechbd.com "or" sales.merlin18@gmail.com"
- Product: PERKINS
- Alternator: ECP 32‐2L/4 C
- CONTROL SYSTEM: DSE 6120
Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.
Certificate
- TS ISO 8528
- TS ISO 9001-2008
- CE
- SZUTEST
- 2000/14/EC
General Characteristics
Model Name | AP 88 |
Frequency (Hz) | 50 |
Fuel Type | Diesel |
Engine Made and Model | PERKINS - 1104A-44TG2 |
Alternator Made and Model | Mecc Alte - ECP 32‐2L/4 C |
Control Panel Model | DSE 6120 |
Canopy | AK 40 |
3 Phase, 50 Hz, PF 0.8
VOLTAGE | STANDBY RATING (ESP) | PRIME RATING (PRP) | Standby Amper | ||
kVA | kW | kVA | kW | ||
400/231 | 88 | 70.4 | 80 | 64.0 | 127.02 |
STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed.
PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.
ENGINE SPECIFICATIONS
Engine | PERKINS | |
Engine Model | 1104A-44TG2 | |
NO. OF CYLINDERS AND BUILD | 4 cylinders - in line | |
BORE AND STROKE | mm | 105 X 127 |
TOTAL DISPLACEMENT | L | 4.4 |
Aspiration | Turbo Charged | |
COMPRESSION RATIO | 17.25:1 | |
RATED SPEED (RPM) | d/dk | 1500 |
OIL CAPACITY | L | 8 |
Standby Power (kW/HP) | 80.7/108,17 | |
Prime Power | 73.4/98,39 | |
Block Heater QTY | 1 | |
Block Heater Power (Watt) | 750 | |
Fuel Type | Diesel | |
Injection Type and System | Direct | |
Type of Fuel Pump | Delphi Rotary Type | |
Governor System | Mechanic | |
Operating Voltage (Vdc) | 12 Vdc | |
Battery and Capacity (Qty/Ah) | 1x66 | |
Charge Alternator (A) | 65 | |
Cooling Method | Water Cooled | |
Coolant Capacity (engine only / with radiator) (lt) | /13 | |
Air Filter | Dry Type | |
Fuel Cons. Prime With %100 Load (lt/hr) | 18.7 | |
Fuel Cons. Prime With %75 Load (lt/hr) | 14 | |
Fuel Cons. Prime With %50 Load (lt/hr) | 9.7 |
ALTERNATOR SPECIFICATIONS
Manufacturer | Mecc Alte | |
Alternator Made and Model | ECP 32‐2L/4 C | |
Frequency (Hz) | Hz | 50 |
Power (kVA) | kVA | 82.5 |
DESIGN | 4 Pole, Brushless | |
VOLTAGE | V | 400 |
Phase | 3 | |
A.V.R. | DSR | |
Voltage Regulation | (+/-) | 1 |
Insulation System | H | |
Protection | IP23 | |
Rated Power Factor | 0.8 | |
WEIGHT COMP. GENERATOR (Kg) | 252 | |
COOLING AIR (m³/min) | m3 | 15.7 |
SIZE and WEIGHT
Open Type | DRY WEIGHT (kg.) | LENGTH | WIDTH | HEIGHT | TANK CAPACITY (lt.) (Lt.) |
1040 | 2150 | 1050 | 1462 | 240 | |
CANOPY | DRY WEIGHT (kg.) | LENGTH | WIDTH | HEIGHT | TANK CAPACITY (lt.) (Lt.) |
AK 40 | 1380 | 3105 | 1113 | 1811 | 240 |
STANDARD SPECIFICATIONS
Water cooled, Diesel engine
Radiator with mechanical fan
Protective grille for rotating and hot parts
Electric starter and charge alternator
Starting battery (with lead acid) including rack and cables
Engine coolant heater
Base frame design incorporates an integral fuel tank and anti-vibration isolators
Flexible fuel connection hoses
Single bearing, class H alternator
Industrial exhaust silencer and steel bellows supplied separately(for open sets)
Static battery charger
Manual for application and installation
OPTIONAL EQUIPMENTS
ENGINE
• Fuel-Water Seperator Filter• Low water level alarm
• Oil heater
ALTERNATOR
• Anti-Condensation Heater• Over sized alternator
• Main line circuit breaker
CONTROL SYSTEM
• Remote annunciator panel• Remote relay output
• Alarm output relays
• Remote communication with modem
• Earth fault, single set
• Charge Ammeter
TRANSFER SWITCH
• Three or four pole contactor• Three or four pole motor operated circuit breaker
OTHER ACCESSORIES
• Main Fuel Tank• Automatic or manual fuel filling system
• Manual oil drain pump
• Residential silencer
• Enclosure: weater protective or sound attenuated
• Duct adapter ( on radiator)
• Inlet and outlet motorised louvers
• Inlet and outlet acoustic baffles
• Trailer
• Tool kit for maintenance
• Supplied with oil and coolant - 30 °C
• Battery isolating switch
Ensuring Uninterrupted Power Supply: The 88 KVA Aksa Diesel Generator (AP88)
In today's world, where electricity powers our homes, businesses, and industries, any disruption in the power supply can be a major setback. Whether you're dealing with power outages in remote locations, need a backup power solution for emergencies, or require a reliable source of electricity for your operations, the 88 KVA Aksa Diesel Generator, specifically the Aksa AP88 model, stands as a trusted choice. In this blog post, we'll explore the features and benefits of the Aksa AP88, highlighting why it's a key player in ensuring uninterrupted power supply.
Reliability in Every Decibel
The Aksa AP88 is renowned for its exceptional reliability. It boasts a powerful 88 KVA (70 kW) output that can easily handle the electricity requirements of various applications, whether it's an essential backup for hospitals, emergency power for data centers, or continuous energy supply for industrial operations. With Aksa's commitment to quality and performance, you can trust the AP88 to deliver consistent, high-quality power.
Efficiency and Cost-Effectiveness
When it comes to diesel generators, efficiency and fuel economy are crucial. The Aksa AP88 is designed to be highly fuel-efficient, helping you save on operational costs. Its advanced engine technology ensures that it makes the most of every drop of fuel, making it an eco-friendly and cost-effective choice for your power needs.
User-Friendly Operation
The Aksa AP88 is equipped with user-friendly controls and monitoring systems. Its intuitive interface allows for easy operation, and it comes with advanced features such as automatic startup and shutdown, as well as remote monitoring capabilities. This ensures that you can rely on the generator to kick in when needed, without manual intervention.
Quiet and Environmentally Friendly
One common concern with diesel generators is noise pollution. However, the Aksa AP88 is designed with noise reduction in mind. Its advanced soundproofing technology minimizes operational noise, making it suitable for both urban and remote locations. Moreover, it meets environmental standards and emissions regulations, ensuring that it's a responsible choice for your power needs.
Versatility for Diverse Applications
The Aksa AP88 is adaptable to a wide range of applications. Whether you need it for standby power, prime power, or continuous power, the AP88 is built to deliver. It's a dependable solution for construction sites, remote off-grid locations, residential backup power, and a variety of industrial purposes.
Maintenance Made Easy
Regular maintenance is essential for keeping any generator in peak condition. The Aksa AP88 simplifies maintenance with convenient access to critical components, reducing downtime and ensuring your generator stays in optimal working order.
Conclusion
The 88 KVA Aksa Diesel Generator, Aksa AP88, is a testament to Aksa's commitment to quality and reliability. Whether you're facing the uncertainties of power outages, require a backup source for emergencies, or need a dependable power supply for your business, the AP88 is designed to meet your needs. With its efficiency, user-friendly operation, quiet performance, versatility, and ease of maintenance, the Aksa AP88 is an ideal choice to ensure uninterrupted power supply. Trust in the AP88, and you can focus on what you do best while your power supply remains rock-solid.