AKSA AC1410 1410 KVA Diesel Generator
EMI Available
Model: AC 1410
Brand: AKSA
0.00 0.00

SpecificationDetails
Model NameAC 1410
Frequency50 Hz
Fuel TypeDiesel
Engine Manufacturer & ModelCUMMINS KTA50-G3
Alternator Manufacturer & ModelMecc Alte ECO 43-2L/4 A
Control PanelDSE 7320
Canopy ModelAK 98
Standby Power1227 kW / 1645 HP
Prime Power1097 kW / 1470 HP
Engine Configuration16 Cylinders, V-Type
Displacement50.3 L
Bore × Stroke159 × 159 mm
AspirationTurbocharged & Aftercooled
Compression Ratio13.9:1
Rated Speed1500 RPM
Oil Capacity177 L
Injection SystemDirect Injection
Fuel PumpCummins PT
Governor SystemElectronic
Operating Voltage24 V DC
Battery4 × 143 Ah
Cooling MethodWater Cooled
Coolant Capacity
161 L (Engine Only) / 415 L (With Radiator)
Air FilterDry Type
Prime Fuel Consumption at 100% Load261 L/hr
Prime Fuel Consumption at 75% Load199 L/hr
Prime Fuel Consumption at 50% Load139 L/hr
Alternator Power1300 kVA
Alternator Voltage400 V
Phase3 Phase
AVRDER1
Voltage Regulation±0.5%
Insulation SystemClass H
ProtectionIP23
Rated Power Factor0.8
Generator Component Weight2660 kg
Open Generator Set Dimensions (L × W × H)4871 × 1940 × 2405 mm
Open Generator Set Dry Weight9900 kg
Open Generator Set Tank Capacity2000 L
Canopy Dimensions (L × W × H)9000 × 2270 × 2581 mm
Canopy Dry Weight14,000 kg
Canopy Tank Capacity1900 L

AKSA AC1410 1410 KVA Diesel Generator – High-Capacity Power for Demanding Sites


When a place needs -stop electricity a power cut can quickly affect production, machines, safety systems and daily work. Big industrial areas require a generator that can deal with electrical loads and keep working well.

The AKSA AC1410 1410 KVA Diesel Generator is built for high-capacity power needs. It has a CUMMINS KTA50-G3 diesel engine, Mecc Alte ECO 43-2L/4 A alternator and DSE 7320 control panel. The listed details show 1227 kW standby power and 1097 kW prime power, which makes this generator a good choice, for commercial, industrial and infrastructure uses.
Key Features
  • 1300 kVA alternator capacity
  • 1227 kW / 1645 HP standby power
  • 1097 kW / 1470 HP prime power
  • CUMMINS KTA50-G3 diesel engine
  • 16-cylinder V-type engine
  • 50.3-liter displacement
  • Turbocharged and aftercooled
  • Mecc Alte ECO 43-2L/4 A alternator
  • DSE 7320 control panel
  • 400 V, 3-phase output
  • 2000-liter open-set fuel tank
  • 1900-liter canopy fuel tank

Why Choose the AKSA AC1410?

High-Capacity Power Output
The AC1410 uses a 1300 kVA Mecc Alte alternator. Delivers 1227 kW standby power. The AC1410 has a 1097 kW rating that supports applications that require sustained generator operation.

For facilities proper generator sizing remains essential. The required capacity should consider the sites running load, motor starting requirements, future expansion and operating schedule.

Powerful CUMMINS KTA50-G3 Engine
The CUMMINS KTA50-G3 has a 16-cylinder V-type configuration with 50.3 liters of displacement. The CUMMINS KTA50-G3 uses turbocharging and aftercooling to support the engines power output.

The engine also uses an injection system Cummins PT fuel pump and electronic governor.

Mecc Alte Alternator
The Mecc Alte ECO 43-2L/4 A alternator provides 1300 kVA at 400 V, 50 three-phase output. The Mecc Alte ECO 43-2L/4 A alternator has a DER1 AVR that provides ±0.5% voltage regulation while Class H insulation and IP23 protection form part of the supplied alternator specification.

Large Fuel Capacity
The AC1410 offers fuel storage for high-load operation. The supplied specifications list:

  • 2000 L tank capacity for the generator set
  • 1900 L tank capacity for the canopy version
Prime fuel consumption is listed at 261 L/hr at 100% load, 199 L/hr at 75% load and 139 L/hr at 50% load. Actual consumption varies with load and operating conditions.
Suitable Installation Options
The generator is available, in canopy configurations. The canopy version measures 9000 × 2270 × 2581 mm. Has a dry weight of 14,000 kg. Because of its size and weight installation requires site planning, access, foundation, ventilation and service arrangements.

Frequently Asked Questions

Q: What is the capacity of the AKSA AC1410 generator?
According to specifications, the generator has 1300 kVA of alternator capacity and has 1227 kW in standby and 1097 kW in prime mode.

Q: What engine has been used in the AKSA AC1410?
The generator uses the CUMMINS KTA50-G3 engine, which is a 50.3 L, 16-cylinder V-type diesel engine.

Q: What alternator is used in AC1410?
The generator is equipped with Mecc Alte ECO 43-2L/4 A alternator rated at 1300 kVA.

Q: What is the fuel consumption of the AC1410?
The fuel consumption for prime operation is 261 L/hr, 199 L/hr for loads of 75%, and 139 L/hr for loads of 50%.


The AKSA AC1410 sets itself apart in the market due to powerful CUMMINS engine and Mecc Alte alternator being built into this generator. Because of high output capacity, it is fit for operations in places where higher amounts of electricity are needed.


To know the generator's suitability, check what actual load is required on a site, starting requirements, installation conditions, fuel storage, ventilation, and access for maintenance needs before buying. Reach out to an approved AKSA supplier for installation, commissioning and maintenance support.