APD110BD Diesel Generator in Bangladesh
EMI Available
Model: APD 110 BD
Brand: AKSA
0.00 0.00

Full Specification of APD 110 BD Diesel Generator:

  • Product: AKSA (Powered by Baudouin)
  • Alternator: AK 480
  • CONTROL SYSTEM: DSE 6120

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.

Certificate

  • TS ISO 8528
  • CE
  • SZUTEST
  • 2000/14/EC

General Characteristics

Model Name

APD 110 BD

Frequency (Hz)

50

Fuel Type

Diesel

Engine Made and Model

AKSA (Powered by Baudouin) - A4CRW41TIG1-4M10G6D0

Alternator Made and Model

Aksa - AK 480

Control Panel Model

DSE 6120

Canopy

ACP 6A


3 Phase, 50 Hz, PF 0.8

VOLTAGE

STANDBY RATING (ESP)

PRIME RATING (PRP)

Standby Amper

kVA

kW

kVA

kW

400/231

110

88.00

100

80.00

158.78


STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed.

PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.


ENGINE SPECIFICATIONS

Engine

AKSA (Powered by Baudouin)

Engine Model

A4CRW41TIG1-4M10G6D0

NO. OF CYLINDERS AND BUILD

4 cylinders - in line

BORE AND STROKE

mm

105 X 118

TOTAL DISPLACEMENT

L

4.087

Aspiration

Turbo Charged and Air to Air AfterCooled

COMPRESSION RATIO

17.5:1

RATED SPEED (RPM)

d/dk

1500

OIL CAPACITY

L

13

Standby Power (kW/HP)

100/134

Prime Power

90/121

Block Heater QTY

1

Block Heater Power (Watt) 

1000

Fuel Type 

Diesel

Injection Type and System 

Direct

Type of Fuel Pump 

Mechanical

Governor System 

Electronic

Operating Voltage (Vdc) 

12Vdc

Battery and Capacity (Qty/Ah) 

1x66

Charge Alternator (A)

55

Cooling Method 

Water Cooled

Cooling Fan Air Flow (m3/min) 

175

Coolant Capacity (engine only / with radiator) (lt) 

9.4/23.6

Air Filter 

Dry Type

Fuel Cons. Prime With %100 Load (lt/hr)

21.25

Fuel Cons. Prime With %75 Load (lt/hr)

16,01

Fuel Cons. Prime With %50 Load (lt/hr)

10.58


SIZE and WEIGHT

Open Type

DRY WEIGHT (kg.)
(kg.)

LENGTH
(mm.)

WIDTH
(mm.)

HEIGHT
(mm.)

TANK CAPACITY (lt.) (Lt.)

1230

2348

1004

1331

CANOPY

DRY WEIGHT (kg.)
(kg.)

LENGTH
(mm.)

WIDTH
(mm.)

HEIGHT
(mm.)

TANK CAPACITY (lt.) (Lt.)

ACP 6A

1480

2600

1058

1590

180


STANDARD SPECIFICATIONS

Water cooled, Diesel engine 
Radiator with mechanical fan 
Protective grille for rotating and hot parts 
Electric starter and charge alternator 
Starting battery (with lead acid) including rack and cables 
Engine coolant heater 
Base frame design incorporates an integral fuel tank and anti-vibration isolators 
Flexible fuel connection hoses 
Single bearing, class H alternator 
Industrial exhaust silencer and steel bellows supplied separately(for open sets) 
Static battery charger 
Manual for application and installation

OPTIONAL EQUIPMENTS

ENGINE
• Fuel-Water Seperator Filter
• Oil heater

ALTERNATOR
• Anti-Condensation Heater
• Over sized alternator
• PMG excitation + AVR
• Main line circuit breaker

CONTROL SYSTEM
• Automatic synchronising and power control system ( multi gen-set Parallel )
• Transition synchronization with mains
• Remote annunciator panel
• Remote relay output
• Alarm output relays
• Remote communication with modem
• Earth fault, single set
• Charge Ammeter

TRANSFER SWITCH
• Three Pole Contactor
• Four Pole Contactor
• Three or four pole motor operated circuit breaker

OTHER ACCESSORIES
• Main Fuel Tank
• Automatic or manual fuel filling system
• Manual oil drain pump
• Electrical oil drain pump
• Low and high fuel level alarm
• Residential silencer
• Enclosure: weater protective or sound attenuated
• Duct adapter ( on radiator)
• Inlet and outlet motorised louvers
• Inlet and outlet acoustic baffles
• Trailer

APD 110 BD Aksa Diesel Generator: Empowering Bangladesh with Uninterrupted Power

In a nation where reliable access to power is paramount, the APD 110 BD Aksa Diesel Generator stands as a beacon of hope for individuals and businesses across Bangladesh. This article delves into the features and advantages of the APD 110 BD Aksa Diesel Generator and how it plays a pivotal role in mitigating the power challenges faced by the people and industries of Bangladesh.

    Dependable Power Source

      In a country where power interruptions are not uncommon, the APD 110 BD Aksa Diesel Generator stands as a reliable source of backup power. Known for its exceptional reliability, this generator ensures a continuous and stable power supply, making it indispensable for homes and industries.

        Efficiency Meets Sustainability

          The APD 110 BD Aksa Diesel Generator epitomizes efficiency in power generation. Its state-of-the-art technology converts fuel into electricity with minimal waste, making it both a cost-effective and eco-friendly solution. This is particularly crucial in Bangladesh, where energy resources are finite, and efficiency matters.

            Customized for Bangladesh

              This generator is tailored to meet the unique energy needs of Bangladesh. With the capacity to handle various loads, it's suitable for a wide range of applications, from small businesses to large manufacturing facilities. Whether it's for household backup or industrial operations, the APD 110 BD Aksa Diesel Generator delivers.

                Eco-Conscious Design

                  As environmental concerns grow globally, the choice of power generation systems must align with sustainability. APD 110 BD Aksa Diesel Generators adhere to strict emission standards, ensuring they have a minimal environmental impact. They are the responsible choice for those seeking to reduce their carbon footprint.

                    Remote Monitoring and Maintenance

                      Keeping your generator in top working condition is simplified with the inclusion of remote monitoring and maintenance features. The APD 110 BD Aksa Diesel Generator can be monitored and serviced from a distance, reducing downtime and ensuring uninterrupted power supply.

                      Local Expertise and Support

                        Access to local experts familiar with the unique energy challenges of Bangladesh is crucial when investing in a power solution. APD 110 BD Aksa Diesel Generator comes with a network of experienced service providers who can assist with installation, maintenance, and any technical issues, ensuring seamless operation.

                        Conclusion

                        In a nation like Bangladesh, where power shortages can be a significant obstacle to progress, the APD 110 BD Aksa Diesel Generator provides a ray of hope. With its reliability, efficiency, and eco-conscious design, it's the ideal solution for the country's energy challenges. By investing in APD 110 BD Aksa Diesel Generators, you can ensure a continuous and dependable power supply, supporting the progress and growth of Bangladesh. Make the smart choice for your power needs, and embrace the APD 110 BD Aksa Diesel Generator as your reliable energy partner in Bangladesh.