Full Specification of APD 275 C Diesel Generator With Details Guide!
- Product: CUMMINS
- Alternator: AK 4200
- CONTROL SYSTEM: DSE 7320
Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.
Certificate
- ISO 14001-2004
- TS ISO 8528
- TS ISO 9001-2008
- CE
- SZUTEST
- 2000/14/EC
General Characteristics
Model Name | APD 275 C |
Frequency (Hz) | 50 |
Fuel Type | Diesel |
Engine Made and Model | CUMMINS - 6LTAA8.9-G2 |
Alternator Made and Model | Aksa - AK 4200 |
Control Panel Model | DSE 7320 |
Canopy | MS 60 CK |
3 Phase, 50 Hz, PF 0.8
VOLTAGE | STANDBY RATING (ESP) | PRIME RATING (PRP) | Standby Amper | ||
kVA | kW | kVA | kW | ||
400/231 | 275 | 220 | 250 | 200 | 396.94 |
STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed.
PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.
ENGINE SPECIFICATIONS
Engine | CUMMINS | |
Engine Model | 6LTAA8.9-G2 | |
NO. OF CYLINDERS AND BUILD | 6 cylinders - in line | |
BORE AND STROKE | mm | 114 X 145 |
TOTAL DISPLACEMENT | L | 8,90 |
Aspiration | Turbo Charged and Charge Air Cooled | |
COMPRESSION RATIO | 16.6:1 | |
RATED SPEED (RPM) | d/dk | 1500 |
OIL CAPACITY | L | 21 |
Standby Power (kW/HP) | 240/322 | |
Prime Power | 220/295 | |
Block Heater QTY | 1 | |
Block Heater Power (Watt) | 1500 | |
Fuel Type | Diesel | |
Injection Type and System | Direct | |
Type of Fuel Pump | BYC P7100 | |
Governor System | Electronic | |
Operating Voltage (Vdc) | 24 Vdc | |
Battery and Capacity (Qty/Ah) | 2x85 | |
Charge Alternator (A) | 70 | |
Cooling Method | Water Cooled | |
Cooling Fan Air Flow (m3/min) | 475 | |
Coolant Capacity (engine only / with radiator) (lt) | 12.3/46.1 | |
Air Filter | Dry Type | |
Fuel Cons. Prime With %100 Load (lt/hr) | 53 | |
Fuel Cons. Prime With %75 Load (lt/hr) | 39 | |
Fuel Cons. Prime With %50 Load (lt/hr) | 27 |
ALTERNATOR SPECIFICATIONS
Manufacturer | Aksa | |
Alternator Made and Model | AK 4200 | |
Frequency (Hz) | Hz | 50 |
Power (kVA) | kVA | 250 |
DESIGN | Brushless | |
VOLTAGE | V | 400 |
Phase | 3 | |
A.V.R. | SX440 | |
Voltage Regulation | (+/-) | 1 |
Insulation System | H | |
Protection | IP22 | |
Rated Power Factor | 0.8 | |
WEIGHT COMP. GENERATOR (Kg) | 727 | |
COOLING AIR (m³/min) | m3 | 34.8 |
SIZE and WEIGHT
Open Type | DRY WEIGHT (kg.) | LENGTH | WIDTH | HEIGHT | TANK CAPACITY (lt.) (Lt.) |
1950 | 2600 | 1250 | 1684 | 473 | |
CANOPY | DRY WEIGHT (kg.) | LENGTH | WIDTH | HEIGHT | TANK CAPACITY (lt.) (Lt.) |
MS 60 CK | 2700 | 3963 | 1356 | 2171 | 470 |
STANDARD SPECIFICATIONS
Water cooled, Diesel engine
Radiator with mechanical fan
Protective grille for rotating and hot parts
Electric starter and charge alternator
Starting battery (with lead acid) including rack and cables
Engine coolant heater
Base frame design incorporates an integral fuel tank and anti-vibration isolators
Flexible fuel connection hoses
Single bearing, class H alternator
Industrial exhaust silencer and steel bellows supplied separately(for open sets)
Static battery charger
Manual for application and installation
OPTIONAL EQUIPMENTS
ENGINE
- Fuel-Water Separator Filter
- Oil heater
ALTERNATOR
- Anti-Condensation Heater
- Main line circuit breaker
CONTROL SYSTEM
- Charge Ammeter
TRANSFER SWITCH
- Three or four pole contactor
- Three or four pole motor operated circuit breaker
OTHER ACCESSORIES
- Main Fuel Tank
- Manual oil drain pump
- Residential silencer
- Enclosure: weater protective or sound attenuated
- Trailer
- Tool kit for maintenance
Powering Progress: The APD275C Diesel Generator in Bangladesh
In a country like Bangladesh, where power interruptions are a common occurrence, having a dependable source of backup electricity is a crucial necessity. The APD275C Diesel Generator is quickly emerging as a reliable solution to address this issue. In this blog post, we will explore the key features and benefits of the APD275C Diesel Generator and discuss why it is increasingly becoming the preferred choice for ensuring an uninterrupted power supply in Bangladesh.
Key Features of the APD275C Diesel Generator
- High Power Output: The APD275C is a robust generator with an impressive capacity of [X] kilowatts. Its substantial power output makes it ideal for a wide range of applications, from homes and businesses to industrial facilities.
- Durable Diesel Engine: Equipped with a rugged and fuel-efficient diesel engine, the APD275C ensures both long-lasting performance and cost-effective operation. Diesel engines are renowned for their reliability, making them an excellent choice in areas with frequent power outages.
- Automatic Transfer Switch (ATS): The built-in ATS system guarantees a seamless transition between the main power supply and the generator, ensuring that your home or business remains operational even during sudden power failures.
- Low Noise Operation: Designed with noise reduction in mind, the APD275C operates quietly, minimizing noise pollution. This makes it a suitable choice for urban and residential environments where noise can be a concern.
- Fuel Efficiency: The APD275C is engineered for fuel efficiency, leading to significant long-term cost savings. In a country where electricity prices can be high, this is an appealing advantage.
Why Choose the APD275C Diesel Generator in Bangladesh?
- Reliable Power Supply: Bangladesh's power grid often faces instability, leading to frequent power cuts. The APD275C offers a dependable backup power source, ensuring uninterrupted power supply to keep your daily operations running smoothly.
- Economic Viability: While the initial investment in a generator may seem substantial, it can lead to considerable cost savings over time. Diesel generators, like the APD275C, are known for their fuel efficiency, making them an economically sound choice.
- Versatility: The APD275C is designed to cater to a wide array of power requirements, from small households to large industrial setups. Its high power output and adaptability make it suitable for diverse applications.
- Environmental Responsibility: Modern diesel generators, including the APD275C, adhere to strict emissions standards and integrate technologies that reduce harmful emissions. This ensures reliable power without compromising on environmental responsibility.
Conclusion
The APD275C Diesel Generator is a formidable solution to the persistent problem of power outages in Bangladesh. With its substantial power output, durable diesel engine, automatic transfer switch, low noise operation, and fuel efficiency, it provides a reliable and cost-effective source of backup electricity. By choosing the APD275C, you can ensure an uninterrupted power supply for your home, business, or industrial operations, regardless of the challenges posed by the power grid.
Investing in the APD275C is a commitment to reliability, resilience, and a brighter, more electrified future for Bangladesh. It is a step toward powering progress and prosperity for all, ensuring that the people and industries of Bangladesh can continue to thrive, even in the face of power challenges.