Diesel Generator Price in Bangladesh
INTRODUCTION
Aksa power generation system, providing optimum performance, and
reliability, for stationary standby, prime power, and continuous duty
applications. All generator sets are factory build, and production tested.
Certificate
- TS ISO 8528
- TS ISO 9001-2008
- CE
- SZUTEST
- 2000/14/EC
General Characteristics
Model Name |
APD 55 A |
Frequency (Hz) |
50 |
Fuel Type |
Diesel |
Engine Made and Model |
AKSA - A4CRX36T |
Alternator Made and Model |
Aksa - AK 340 |
Control Panel Model |
DSE 6120 |
Canopy |
ACP 5 |
3 Phase, 50 Hz, PF 0.8
VOLTAGE |
STANDBY RATING (ESP) |
PRIME RATING (PRP) |
Standby Amper |
||
kVA |
kW |
kVA |
kW |
||
400/231 |
55 |
44.00 |
50 |
40.00 |
79.39 |
STANDBY RATING (ESP) : Applicable for supplying power to varying
electrical load for the duration of power interruption of a reliable utility
source. ESP is in accordance with ISO 8528-1. Overload is not allowed.
PRIME RATING (PRP) : Applicable for supplying power to varying electrical
load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload
capability is available for a period of 1 hour within 12-hour perod of
operation.
ENGINE SPECIFICATIONS
Engine |
AKSA |
||
Engine Model |
A4CRX36T |
||
NO. OF CYLINDERS AND BUILD |
4 cylinders - in line |
||
BORE AND STROKE |
mm |
98 X 120 |
|
TOTAL DISPLACEMENT |
L |
3.6 |
|
Aspiration |
Turbo Charged |
||
COMPRESSION RATIO |
17.5:1 |
||
RATED SPEED (RPM) |
d/dk |
1500 |
|
OIL CAPACITY |
L |
10 |
|
Standby Power (kW/HP) |
51/68 |
||
Prime Power |
46/61 |
||
Block Heater QTY |
|||
1 |
|||
Block Heater Power (Watt) |
|||
500 |
|||
Fuel Type |
|||
Diesel |
|||
Injection Type and System |
|||
Direct |
|||
Type of Fuel Pump |
|||
4JI |
|||
Governor System |
|||
Mechanic |
|||
Operating Voltage (Vdc) |
|||
12 Vdc |
|||
Battery and Capacity (Qty/Ah) |
|||
1x54 |
|||
Cooling Method |
|||
Water Cooled |
|||
Coolant Capacity (engine only / with radiator) (lt) |
|||
5/16 |
|||
Air Filter |
|||
Dry Type |
|||
Fuel Cons. Prime With %100 Load (lt/hr) |
|||
12.4 |
ALTERNATOR SPECIFICATIONS
Manufacturer |
Aksa |
|
Alternator Made and Model |
AK 340 |
|
Frequency (Hz) |
Hz |
50 |
Power (kVA) |
kVA |
50 |
DESIGN |
4 Pole, Brushless |
|
VOLTAGE |
V |
400 |
Phase |
3 |
|
A.V.R. |
SX460 |
|
Voltage Regulation |
(+/-) |
1.5% |
Insulation System |
H |
|
Protection |
IP22 |
|
Rated Power Factor |
0.8 |
|
WEIGHT COMP. GENERATOR (Kg) |
285 |
|
COOLING AIR (m³/min) |
m3 |
12,96 |
SIZE and WEIGHT
Open Type |
DRY WEIGHT (kg.) |
LENGTH |
WIDTH |
HEIGHT |
TANK CAPACITY (lt.) (Lt.) |
- |
- |
- |
- |
||
CANOPY |
DRY WEIGHT (kg.) |
LENGTH |
WIDTH |
HEIGHT |
TANK CAPACITY (lt.) (Lt.) |
ACP 5 |
1170 |
2282 |
1008 |
1532 |
180 |
STANDARD SPECIFICATIONS
- Water cooled, Diesel engine
- Radiator with mechanical fan
- Protective grille for rotating and hot parts
- Electric starter and charge alternator
- Starting battery (with lead acid) including rack and cables
- Engine coolant heater
- Base frame design incorporates an integral fuel tank and anti-vibration isolators
- Flexible fuel connection hoses
- Single bearing, class H alternator
- Industrial exhaust silencer and steel bellows supplied separately(for open sets)
- Static battery charger
- Manual for application and installation
OPTIONAL EQUIPMENTS
ENGINE
- Remote Radiator Cooling
- Fuel-Water Seperator Filter
ALTERNATOR
- Anti-Condensation Heater
- Main line circuit breaker
CONTROL SYSTEM
- Charge Ammeter
- TRANSFER SWITCH
- Three Pole Contactor
- Four Pole Contactor
- Three or four pole motor operated circuit breaker
OTHER ACCESSORIES
- Main Fuel Tank
- Automatic or manual fuel filling system
- Manual oil drain pump
- Residential silencer
- Enclosure: weater protective or sound attenuated
- Trailer
- Tool kit for maintenance