ASKA AP165 165 KVA Aksa Diesel Generator
EMI Available
Model: AP 165
Brand: AKSA
0.00 0.00

Full Specification of AP 165 Diesel Generator With Details Guide!

For Quotation Please Contact:

Mobile/WhatsApp: +880 1816 553327 "or" +880 1730848516

E-Mail: "info@merlintechbd.com "or" sales.merlin18@gmail.com"


  • Product: PERKINS
  • Alternator: ECP 34-1L/4 C
  • CONTROL SYSTEM: DSE 6120

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.

Certificate

  •   TS ISO 8528
  •   TS ISO 9001-2008
  •   CE
  •   SZUTEST
  •   2000/14/EC
SpecificationDetails
Model NameAP 165
Frequency50 Hz
Fuel TypeDiesel
Engine Manufacturer & ModelPERKINS 1106A-70TAG2
Alternator Manufacturer & ModelMecc Alte ECP 34-1L/4 C
Control PanelDSE 6120
CanopyAK 49
Phase3 Phase
Voltage400/231 V
Power Factor0.8
Standby Rating (ESP)165 kVA / 132.0 kW
Prime Rating (PRP)150 kVA / 120.0 kW
Standby Current238.16 A
EnginePERKINS
Engine Model1106A-70TAG2
Number of Cylinders6 Cylinders, Inline
Bore × Stroke105 × 135 mm
Total Displacement7.01 L
AspirationTurbocharged and Charge Air Cooled
Compression Ratio18.2:1
Rated Speed1500 RPM
Oil Capacity18 L
Standby Power149.1 kW / 199.86 HP
Prime Power136 kW / 182.30 HP
Block Heater Quantity1
Block Heater Power1500 W
Injection Type & SystemDirect Injection
Fuel Pump TypeDelphi DP210G Rotary Type
Governor SystemMechanical
Operating Voltage12 VDC
Battery1 × 85 Ah
Charge Alternator65 A
Cooling MethodWater Cooled
Coolant Capacity21 L with Radiator
Air FilterDry Type
Fuel Consumption at 100% Load (PRP)33.4 L/hr
Fuel Consumption at 75% Load (PRP)24.7 L/hr
Fuel Consumption at 50% Load (PRP)16.4 L/hr
Alternator ManufacturerMecc Alte
Alternator ModelECP 34-1L/4 C
Alternator Power150 kVA
Alternator Design4 Pole, Brushless
Alternator Voltage400 V
Alternator Phase3 Phase
AVRDSR
Voltage Regulation±1%
Insulation SystemClass H
ProtectionIP23
Rated Power Factor0.8
Generator Weight Component423 kg
Cooling Air29.2 m³/min
Open Type Dry Weight1380 kg
Open Type Dimensions (L × W × H)2300 × 1080 × 1667 mm
Open Type Tank Capacity340 L
Canopy ModelAK 49
Canopy Dry Weight1975 kg
Canopy Dimensions (L × W × H)3402 × 1147 × 2007 mm

Canopy Tank Capacity


ASKA AP165 165 KVA Diesel Generator for Reliable Power Backup

A reliable generator matters when the regular power supply cannot be counted on. For a factory, office, commercial building, or other facility, the generator needs to handle the required electrical load without creating unnecessary complications during operation.

The ASKA AP165 165 KVA Aksa Diesel Generator is built around a PERKINS 1106A-70TAG2 diesel engine and a Mecc Alte ECP 34-1L/4 C alternator. The set is controlled through a DSE 6120 control panel, giving the operator access to the main operating information of the generator.

The AP165 has a 165 kVA standby rating and a 150 kVA prime rating. It works at 400/231 V, 50 Hz, 3 phase, with a rated power factor of 0.8. These specifications make the unit suitable for installations where dependable backup or regular prime power is required.

Engine and Generator Setup

The engine is one of the main parts to consider when choosing a diesel generator. The ASKA AP165 uses the PERKINS 1106A-70TAG2, a six-cylinder inline engine with a 7.01-liter displacement. It operates at 1500 RPM and uses direct fuel injection.

The engine is also turbocharged and charge air cooled. Its cooling system is water based, which is commonly used for generator sets in this power range. The supplied engine configuration includes a mechanical governor, 12 Vdc operating system, 85 Ah battery and 65 A charge alternator.

On the generator side, the AP165 uses a Mecc Alte ECP 34-1L/4 C alternator. It is a four-pole, brushless alternator with a DSR AVR. The alternator has Class H insulation, IP23 protection and voltage regulation of ±1%.

This combination gives the generator a straightforward setup: a well-known diesel engine, a dedicated alternator and a control system designed for generator operation.

Standby and Prime Power

The AP165 is rated differently for standby and prime operation.

Its standby rating is 165 kVA / 132 kW, while the prime rating is 150 kVA / 120 kW.

Standby power is intended for situations where the generator operates during interruptions of the utility supply. Prime power is used when the generator may need to carry a varying electrical load for extended periods.

Choosing between these ratings should depend on the actual load profile of the site. Motors, pumps, compressors and other equipment with higher starting requirements should also be considered before finalizing the generator size.

DSE 6120 Control Panel

The DSE 6120 control panel is another important part of the AP165 package. It allows the operator to monitor the generator and manage its operating functions from the control panel.

For installations where the generator needs regular monitoring, having a dedicated controller makes day-to-day operation more convenient. The exact control and protection functions available should be checked against the supplied configuration before installation.

Open and Canopy Options

The ASKA AP165 is available in an open-type configuration as well as with an AK 49 canopy.

The open version has a dry weight of approximately 1380 kg and measures 2300 × 1080 × 1667 mm. The canopy version weighs approximately 1975 kg and measures 3402 × 1147 × 2007 mm.

The enclosed canopy can be useful when the generator needs additional protection as part of the installation setup. Available space, ventilation, access for maintenance and site conditions should be checked before installation.

Frequently Asked Questions

Q: What is the capacity of the ASKA AP165 generator?

The ASKA AP165 is rated at 165 kVA standby power and 150 kVA prime power.

Q: Which engine does the AP165 use?

It uses the PERKINS 1106A-70TAG2, a six-cylinder inline diesel engine with a 7.01-liter displacement.

Q: Which alternator is used?

The generator is equipped with a Mecc Alte ECP 34-1L/4 C four-pole brushless alternator with DSR AVR.

Q: What are the voltage and frequency ratings?

The rated output is 400/231 V, 50 Hz, 3 phase, with a power factor of 0.8.

Q: Does the generator come with a canopy?

Yes. The supplied configuration includes an AK 49 canopy option, in addition to the open-type configuration.

The ASKA AP165 165 KVA Aksa Diesel Generator is built around a practical combination of PERKINS engine technology, Mecc Alte alternator technology and a DSE 6120 controller.


Its 165 kVA standby and 150 kVA prime ratings provide flexibility for different power requirements. The available open and canopy configurations also make it easier to plan the generator around the installation environment.


Before selecting the AP165, the actual electrical load, motor starting requirements, available installation space and expected operating conditions should be checked. Proper sizing at the beginning can make a significant difference to generator performance and long-term operation.


For generator supply, installation, servicing and spare parts support, contact Merlin Tech Limited.